Lumens vs Lux vs Candela: Reading a Work Light Spec Sheet
Lumens measure the total light a work light gives out; lux measures how much of that light lands on a surface (1 lux = 1 lumen per square metre); candela measures how intense the beam is in one direction, which sets how far it reaches. Flood lights are compared by lumens and beam angle, spotlights by candela and beam distance. All 37 of our models with a stated output are listed in lumens, from 180 to 3,000 lm.
| Unit | What it measures | Use on work lights |
|---|---|---|
| Lumen (lm) | Total light output of the lamp | Compare overall output of flood and area lights |
| Lux (lx) | Light landing on a surface: lumens per m² | How bright the work area is at a given distance |
| Candela (cd) | Light intensity in one direction | Compare spotlights and torches |
| Beam distance (m) | Distance at which the beam falls to 0.25 lux (ANSI/PLATO FL1); equals 2 × √cd | Torches and searchlights |
| Same beam, further away | Illuminance | Why |
|---|---|---|
| 1 m | 400 lx | Example starting value |
| 2 m | 100 lx | Twice the distance → a quarter of the light per m² |
| 4 m | 25 lx | Inverse-square law: lux falls with the square of distance |
Our figures come from our product catalogue (updated 2026-11-16); general guidance describes typical values, not a guarantee for every product.
Why do two 1,000-lumen work lights look different?
Because the same lumens can be spread over a wide or a narrow area. A wide COB panel spreads light evenly with few shadows; a narrow beam puts more lux on a smaller spot and reaches further. Beam angle matters as much as the lumen figure — see flood vs spot work lights.
Why don't most work-light specs show candela?
Most work lights are wide-beam flood lights, where lumens and beam angle say more. Candela and beam distance are mainly used for torches and spotlights. 4 of our listings give an approximate range (RC-W21016 (About 100m), RC-W23003 (50-100m), RC-W23113 (About 100m), ZJ-8859 (50-100m)) without a stated measurement method; before printing a beam distance on your packaging, ask for it measured to ANSI/PLATO FL1.
How can an importer compare work lights when the specs use different units?
Compare lumens and runtime for each mode from the spec sheet, then check samples side by side: measure lux at the same distance (for example 1 m) with a lux meter. See the sample checklist and compare all models in the spec finder.
From our range
Models to compare


3-Panel Foldable Flood Work Light
- Output
- 3,000 lm
- Battery
- 4,400 mAh
- Rating
- IP44


3-Head Rotating Flood Work Light
- Output
- 2,500 lm
- Battery
- 5,400 mAh
- Rating
- IP44


Triple-COB Flood Light, Power-Bank Output
- Output
- 2,000 lm
- Battery
- 3,600 mAh
- Rating
- IP44


2-in-1 Magnetic Stick Light
- Output
- 2,000 lm
- Battery
- 2,000 mAh
- Rating
- IP44
FAQ
More questions
How many lux is 1,000 lumens?
It depends on the area lit: 1,000 lm spread evenly over 1 m² is 1,000 lx, over 4 m² it is 250 lx. In practice it is lower, because not all the light lands on the work area.
Should a floodlight be compared by lux or lumens?
Use lumens and beam angle from the spec sheet to shortlist, and lux at a fixed distance to check samples. See our rechargeable floodlights.
Request samples or a quote
Tell us what you need
Product type and quantity are enough for a first price; add model numbers if you have them. Add your logo and target market if you need private label.
- MOQ 500 pcs per model
- Bulk lead time 7–35 days
- Sample cost quoted per model before anything is sent
Or email sales6@nhruichi.com